NMR probes
NMR SERVICE develops customised solid-state NMR/NQR probes for any magnet/cryostat type and size including wide- and standard/narrow-bore superconducting magnets, electromagnets, liquid Helium/Nitrogen or cryogen-free cryostat systems.
Static NMR
• Single- or double-channel (multi-channel subject to discussion)
• Automatic tune/match
• Magnetic fields beyond 700 MHz
• Single- or double-axis goniometer (manual or automatic)
• Low-temperature probes down to liquid Helium
• High-temperature probes up to 800°C
Low-temperature NMR/NQR
• Temperature range 1.5 to 425 K
• Temperature stability 0.1 K
• Internal Cernox temperature sensor
• Compatible with any temperature controller, e.g. Lakeshore
• Suitable for any cryostat/magnet system including PPMS
• Suitable for cryogen-free cryostat/magnet systems
• Suitable for closed-cycle cryostat/magnet systems
• RF/tuning range optimised as specified by the user
• Wideline/broadband or ultra-wideline frequency range
• Single- or double-channel
• Automatic tune/match
• Single- or double-axis goniometer (manual or automatic)
High/variable-temperature NMR
• Temperature range -100 to 300°C
• Ultra-high temperature range up to 800°C (water-cooled sample area)
• Increased heater capacity, isolation, and temperature shielding
• Adaption of materials close to sample area (Vespel)
• Heating: dry air or nitrogen gas
• Cooling: cooled nitrogen gas (e.g. LN2 exchanger, BCU, etc.)
• Frame flush/cooling
• Compatible with any heater system, e.g. Bruker BVT or NMR SERVICE controller
• Compatible with any temperature controller, e.g. Bruker or NMR SERVICE controller
• Multiple internal temperature sensors
• Temperature sensor: Type N thermocouple (Bruker compatible; others possible)
• Heat gas exhaust with temperature sensor
• Suitable for any magnet and console
• Suitable for wide- and standard/narrow-bore magnets
• Single- or double-channel
• Automatic tune/match
MAS / LED MAS NMR
• Stator: Bruker DVT type 2.5, 3.2, 4.0, or 7.0 mm made of Vespel
• Stator: Phoenix NMR/Varian pencil type of any dimension
• Single- or double-channel (H—X or F—X)
• Triple-channel probes are subject to discussion
• Automatic tune/match
• Magnetic fields beyond 700 MHz
• LED MAS NMR probes combining optics and NMR experiments while spinning
• 3D printed stator/rotor modules
Controller
AUTOTUNE
• Suitable for eATM ROBOT and NMR SERVICE probes
• Compatible with any console, e.g. Bruker (Av. III HD, Neo), Tecmag, Varian
• Compatible with any NMR software, e.g. Bruker TopSpin, TNMR
AUTOTUNE H/F-X controller
• Two-channel AUTOTUNE controller unit
• Enables automatic tune/match for eATM ROBOT and NMR SERVICE probes
• Total frequency range: 30 - 900 MHz
• Usable frequency range depends on probe/console
• Includes interface to console
• Synchronisation via TTL:
• USB interface to computer/software
• Option: upgrade with third channel
AUTOTUNE—H/F and AUTOTUNE—X software
• Enables manual and automatic tune/match via AUTOTUNE controller
• Runs on MS Windows 11 and lower versions
• Synchronisation with the pulse sequence via preamble
• Probe selection menu and/or probe identifier module
• Maximum flexibility in re-calibration
H/F-X eATM ROBOT
• Double-channel external automatic tuning matching (eATM) robot
• Stand-alone unit with hard- and software
• Suitable for any NMR/NQR experiments that require automatic re-calibration of the resonance circuit (tune/match)
• Suited for H/F—X or X—Y or similar static and MAS probes
• Suitable for any magnet and fields of 100 MHz to 1 GHz
• Suitable for any NMR console
• Robot unit with four motor/encoder units for H/F—X tune/match
• Floor plate to position robot underneath the magnet
• Fingertips to attach tune/match elements of the probe to the robot
• Electronics and interface to AUTOTUNE controller
• Hardware fitted to customer requirements
• Option: upgrade to third channel, e.g. for H/F—X—Y probes
MAS Controller (IV)
• Stand-alone unit including hard- and software
• Suitable for all rotor types and consoles
• Manual drive/bearing adjustment (full manual operation)
• Automatic settings (touchpad/software control)
• Remote control via Ethernet (e.g. VNC) on any device
• Eject/insert and frame flush outputs
• MAS spin speed detection to 150 kHz (theoretically 300 kHz with 0.1 Hz resolution; Bruker or any other input
• Spin speed input: digital TTL or analogue with automatic gain calibration
• Signal monitoring output (voltages)
• Trigger signal for synchronisation
• Data logging of all system parameters every 50 ms
• Free soft- and firmware upgrades
• Input Voltage: 100 – 240 V (AC) 50/60 Hz
• Input pressure:
• min. 5 to max. 10 bar (min. 72 to max. 140 psi)
• Output pressure:
• min. 0 to max. 4.5 bar (min. 0 to max. 65 psi) on drive/bearing
• In/output: compressed air or nitrogen gas
Goniometer Controller
• Stand-alone unit including hard- and software
• Suitable for single- and two-axis goniometer
• Manual and automatic (TTL synchronised) mode
• Automatic settings (touchpad/software control)
• Remote control via Ethernet (e.g. VNC) on any device
• Trigger signal for synchronisation
• Data logging of all system parameters every 50 ms
• Free soft- and firmware upgrades
• Input Voltage: 100 – 240 V (AC) 50/60 Hz
VT and Flow Controller
• standalone unit including hard- and software for VT and/or flow control
• rack mount possible
• single channel or dual channel
• operation modes:
flow control only
temperature control with internal flow control (typical for static NMR experiments)
temperature control with external flow control (typical for MAS NMR experiments) (interlock required)
• graphical PC software for monitoring or controlling
• experiment automation for both Bruker and Tecmag type experiments
• thermocouple and sample temperature sensor type selectable in software
• temperature range -270°C to +900°C
• flow range 5 l/min to 30 l/min
• adjustable PID settings from 0 PID to 100/50/20 PID
NMR accessories
Preamplifiers
0.7 - 150 MHz module
• Input frequency: 0.7 – 150 MHz
• Max. input peak power: 30 dBm (20 Vpp / 1 W)
• Noise figure: ≤ 1.3 dB
• Signal amplification (gain): +35 dB (min.)
• Recovery time: ≤ 9 μs (after 1 μs 30 dBm pulse)
• Input / output impedance: 50 Ω nominal
• Input / output VSWR: ≤ 1.4
• Requires +12 (or max. +15) V (DC) power supply
• Option: customised external power supply
• Dimensions: 140 × 55 × 32 mm (L × W × H)
• Temperature: 0 to 50°C
• Humidity: Max. 95% not condensing
20 - 1200 MHz module
• Input Frequency: 20 MHz – 1200 MHz
• Max. Input Peak Power: 30 dBm (20 Vpp) 1 W
• Noise figure: ≤ 1.5 dB
• Signal amplification (gain): +20 dB
• Recovery time: < 1.6 μs (after 1μs 30 dBm pulse)
• Input impedance: 50 Ω nominal
• Input / output VSWR: ≤ 3.0
• Requires +12 - 14 V (DC) power supply
• Option: customised external power supply
• Dimensions: 140 × 55 × 32 mm (L × W × H)
• Temperature: 0 to 50°C
• Humidity: Max. 95% not condensing
REDOR Box
REDOR Box splits a single X-channel (e.g. of a Bruker H—X MAS probe) into a double-resonance circuit to enable X—Y Rotational Echo Double Resonance (REDOR) and similiar NMR experiments.
Options:
• Large REDOR Box: fields of 200 - 600 MHz
• Small REDOR Box: fields of 700 - 900 MHz
Specifications:
• Up to 1000 W RF pulse power (50 μs)
• VSWR < 1.2
• Frequency splitting 1 - 20 MHz, e.g. 13C/23Na, 13C/27Al
• Larger frequency splitting is subject to discussion
• Suitable for Bruker 4.0 and 3.2 mm H—X(—Y) MAS probes (X channel)
• Suitable for DNP experiments
• Suitability for other MAS rotor/probe sizes is subject to discussion
• The box is not suited for the 1H/19F channel
• The H channel can be used with the REDOR Box attached to X
• The Y channel can still be used with the REDOR Box attached to X
• Simple installation/mounting directly at the probe
• N-type connectors
• Efficiency of up to 80% compared to single resonance probe
MAS accessories
• Stators Bruker DVT type 2.5, 3.2, 4.0, or 7.0 mm made of Vespel
• Stators Phoenix NMR/Varian pencil type of any dimension
• MAS rotors for 2.5, 3.2, 4.0, and 7.0 mm (Bruker/Cortecnet)
• Spin speed detection modules
• MAS stator/rotor test stand
• Rotor cap/bottom remover tool (Bruker 2.5, 3.2, 4.0, and 7.0 mm)
• Rotor cap/bottom assembly tool (Bruker 2.5, 3.2, 4.0, and 7.0 mm)